Lahti Precision TPL-300 User Manual
The TPL-300 is a digital load cell amplifier designed for field installation in silo and tank weighing and level monitoring. It works with all types of strain‑gauge load cells and offers features such as auto‑tare, peak hold, and set‑point relays.
The manual covers calibration using the built‑in programmer or an external device, describes the analog (4–20 mA, 0–10 V) and serial (RS‑232/RS‑485) outputs, outlines environmental limits, power requirements, and mechanical construction options (plastic, die‑cast, stainless steel, IP65).
Covers: Product Overview · Calibration Procedure · Accuracy and Performance · Electrical Connections · Analog and Serial Outputs · Mechanical Construction
Latest Lahti manuals
Lahti Precision TPL-300 User Manual
User Manual 2 pages · 201 KB · ENThe Lahti Precision TPL-300 user manual provides specifications, calibration instructions, and installation details for the digital load cell amplifier.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Lahti manuals
How is the TPL-300 calibrated?
Calibration is performed at two points (e.g., 0 and max) by entering the loading data into the device’s memory using the built‑in programmer or an external programming device.
What output options does the TPL-300 provide?
It offers galvanically isolated analog outputs of 4–20 mA and 0–10 V, as well as serial communication via RS‑232 and RS‑485 with selectable baud rates.