iTrust Manuals

ManualLib has 4 iTrust manuals covering 3 models. The most documented models are 3KVA, 2KVA, 1KVA. Every file can be read online or downloaded as a PDF for free.

User Manual 4

Key facts

Manuals
4
Models
3
Languages
ZH
Last added
2000-01-01

iTrust models by category

Other 3

Latest iTrust manuals

  • iTrust UPS 1kVA/2kVA/3kVA User Manual

    User Manual 46 pages · 881 KB · ZH

    The iTrust UPS 1kVA/2kVA/3kVA User Manual provides safety guidelines, installation steps, operation instructions, and specifications for the UPS series.

  • iTrust UH31 Series UPS User Manual

    User Manual 32 pages · 1.1 MB · ZH

    The iTrust UH31 series UPS manual provides installation, operation, maintenance, and troubleshooting guidance for 10/15/20 kVA models.

  • iTrust 1kVA/2kVA/3kVA UPS User Manual

    User Manual 46 pages · 881 KB · ZH

    The iTrust UPS manual provides safety guidelines, installation steps, operation modes, maintenance procedures, and specifications for 1kVA, 2kVA, and 3kVA…

  • iTrust 6kVA/10kVA UPS User Manual

    User Manual 49 pages · 1.1 MB · ZH

    The iTrust 6kVA/10kVA UPS User Manual provides installation, operation, maintenance, and troubleshooting instructions for the UPS series.

Which document do I need?

User Manual

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in iTrust manuals

How should the battery be replaced?

Battery replacement must be performed by authorized service personnel after the UPS is completely powered down and disconnected.

From: iTrust UPS 1kVA/2kVA/3kVA User Manual

What are the operating temperature limits for the UPS?

The UPS operates safely between 0 °C and +40 °C.

From: iTrust UPS 1kVA/2kVA/3kVA User Manual

Can I open the UPS chassis myself?

Only authorized personnel may open the chassis; doing so risks electric shock and voids the warranty.

From: iTrust UH31 Series UPS User Manual

What size circuit breaker is required for the UPS input?

For the 10 kVA model use a three‑pole breaker rated >100 A; for 15 kVA/20 kVA models use a three‑pole breaker rated >160 A.

From: iTrust UH31 Series UPS User Manual

How should the UPS be moved safely?

Before moving the UPS, disconnect the input power and make sure the unit is completely stopped to avoid any remaining output voltage.

From: iTrust 1kVA/2kVA/3kVA UPS User Manual

What are the allowed operating temperature and humidity ranges?

The UPS can operate in temperatures from 0 °C to 40 °C and relative humidity from 5 % to 95 %.

From: iTrust 1kVA/2kVA/3kVA UPS User Manual