The HB100 is a miniature X‑Band bi‑static Doppler transceiver module that includes a dielectric resonator oscillator (DRO) and a microstrip patch antenna. It is intended for motion detection applications such as infrared alarm reduction, auto‑door opening, vehicle speed measurement, lighting control, and long‑range detection.
The document provides a connection diagram, mechanical dimensions, electrical specifications, and safety notes. All measurements are taken with a +5 VDC supply, CW operation, and an ambient temperature of +25 °C unless otherwise noted.
Covers: Introduction · Mechanical Dimensions · Connection Diagram · Electrical Specifications · Operating Notes

AgilSense HB100 Microwave Sensor Module Datasheet
The HB100 is a miniature X‑Band Doppler radar sensor module with a built‑in dielectric resonator oscillator. It is designed for applications such as motion detection, infrared‑PIR alarm reduction, auto‑door opening and vehicle speed measurement.
The document provides a block diagram, mechanical drawings, electrical connection details, a full parameter table and safety notes for handling the electro‑static‑sensitive device.
Covers: Block Diagram and Connection · Connection Hole Chart · Parameter Specifications · Notes · Certificate
Latest AgilSense manuals
AgilSense HB100 Microwave Sensor Module User Manual
User Manual 3 pages · 644 KB · ENUser manual for the AgilSense HB100 miniature microwave motion sensor module with specifications and connection details.
AgilSense HB100 Microwave Sensor Module Datasheet
Datasheet 3 pages · 644 KB · ENTechnical specifications, connection diagrams and usage notes for the AgilSense HB100 microwave sensor module.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Datasheet
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in AgilSense manuals
What supply voltage does the HB100 module require?
The module operates from 4.75 V to 5.25 V DC.
How much current does the HB100 draw during operation?
Typical current consumption is between 30 mA and 40 mA.