Key facts
- Manuals
- 1
- Languages
- EN
- Last added
- 2011-12-11
Featured 3ND manuals

City Technology 3ND Nitrogen Dioxide Sensor Datasheet
The 3ND nitrogen dioxide CiTiceL from City Technology is a compact gas sensor designed for air monitoring. It offers a nominal detection range of 0‑100 ppm with a maximum overload of 1000 ppm and is rated for two years of operation in air.
Key performance data include a response time under 35 seconds, a temperature range of roughly –20 °C to 50 °C, and a pressure coefficient of 0.037 %/mBar. The sensor can be ordered with side tags, gold‑plated PCB pins, or both, and is supplied with a 33 Ω recommended load resistor. Warranty is 12 months from shipment.
Covers: Performance Characteristics · Physical Characteristics · Temperature Dependence · Cross‑sensitivity Data · Ordering Information · Warranty and Storage
Latest 3ND manuals
City Technology 3ND Nitrogen Dioxide Sensor Datasheet
Datasheet 74 pages · 4.5 MB · ENThe City Technology 3ND nitrogen dioxide sensor datasheet provides performance specs, operating ranges, and ordering options.
Which document do I need?
Datasheet
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in 3ND manuals
What is the nominal detection range of the 3ND sensor?
The sensor detects nitrogen dioxide from 0 to 100 ppm.
How fast does the 3ND sensor respond to a change in gas concentration?
Its response time is less than 35 seconds.