Key facts
- Manuals
- 1
- Languages
- EN
- Last added
- 2026-10-03
Featured EIKO SOKKI manuals

EIKO SOKKI EP-500 / EPA-300 Electronic Regulator Instruction Manual
The manual describes the EP-500 electronic regulator paired with the EPA-300 booster amp. It details the unit composition, technical specifications, and required clean air supply for reliable operation.
Installation procedures, pneumatic circuit diagrams, wiring guidelines, adjustment steps, and routine maintenance are provided to ensure proper setup and long‑term performance.
Covers: Composition · Specification · Installation · Pneumatic Circuit · Piping · Wiring
Latest EIKO SOKKI manuals
EIKO SOKKI EP-500 / EPA-300 Electronic Regulator Instruction Manual
User Manual 11 pages · 526 KB · ENInstruction manual for the EP-500 electronic regulator and EPA-300 booster amp, covering composition, specs, installation, wiring, adjustment, and maintenance.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in EIKO SOKKI manuals
How should the output current of the booster amp be adjusted?
The output current is set by factory‑adjusted VRs; reference values are 4 mA at 0 V and 20 mA at 5 V, with a tolerance of ±0.1 mA.
From: EIKO SOKKI EP-500 / EPA-300 Electronic Regulator Instruction Manual
What type of air supply is required for the electronic regulator?
Clean, dry air filtered and free of oil mist is required; supply pressure should be adjusted with a manual regulator.
From: EIKO SOKKI EP-500 / EPA-300 Electronic Regulator Instruction Manual