Guangzhou CNC GSK928T Series Lathe CNC System User Manual
This manual provides detailed instructions for the GSK928T series lathe CNC system, including programming, operation, and connection procedures. It is intended for qualified personnel who will install, configure, and operate the system safely.
Safety is emphasized throughout, with requirements for proper emergency‑stop wiring, grounding resistance (≤0.1 Ω), and protection against dust, moisture, and corrosive gases. Users must also consult the machine‑tool manufacturer's documentation for complementary safety and usage guidelines. This manual is written in Chinese.
Covers: Safety Precautions · Technical Specifications · Operation Panel Description · System Operation · Programming · Interface Overview

Guangzhou CNC Isolation Transformer User Manual
The manual describes the scope, features, applications, operating conditions, and technical data of Guangzhou CNC isolation transformers. It also outlines the responsibilities of manufacturers and users, emphasizing safe handling and proper training.
Key sections cover safety precautions, detailed specifications, installation steps, wiring requirements, grounding, and regular maintenance procedures to ensure reliable and safe operation of the transformers in industrial and commercial environments. This manual is written in Chinese.
Covers: Applicable Scope · Product Features · Product Uses · Operating Conditions · Technical Specifications · Safety Responsibilities
Latest Guangzhou CNC manuals
Guangzhou CNC GSK928T Series Lathe CNC System User Manual
User Manual 368 pages · 21.6 MB · ZHChinese user manual for the GSK928T series CNC system covering operation, programming, installation and safety.
Guangzhou CNC Isolation Transformer User Manual
User Manual 12 pages · 478 KB · ZHThis manual provides safety guidelines, technical specifications, installation, operation, and maintenance instructions for Guangzhou CNC isolation…
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Guangzhou CNC manuals
How should the emergency‑stop button be connected?
The emergency‑stop input uses normally‑closed contacts; if the button is not connected correctly or wired as normally‑open, the system will alarm and will not operate.
From: Guangzhou CNC GSK928T Series Lathe CNC System User Manual
What is the required resistance for protective grounding?
The protective‑ground resistance must be less than or equal to 0.1 Ω.
From: Guangzhou CNC GSK928T Series Lathe CNC System User Manual
What minimum insulation resistance is required between windings and to the enclosure?
The insulation resistance must be at least 20 MΩ.
What are the recommended ambient temperature limits for operation?
The transformer can operate in ambient temperatures from –10 °C to +40 °C.