Key facts
- Manuals
- 4
- Languages
- ZH
- Last added
- 2026-09-29
Featured Angni manuals

Angni AM110W-T Laboratory Electric Mixer User Manual
This manual introduces the Angni AM110W-T laboratory electric mixer, detailing its components, technical specifications, and safety precautions. It includes a complete parts list, assembly instructions, and guidance on proper use and maintenance.
The document also explains the control panel functions, stirring bar options, and troubleshooting steps, as well as warranty information and service contacts to ensure reliable operation in laboratory environments. This manual is written in Chinese.
Covers: Product Overview · Technical Parameters · Parts List and Packing · Assembly Instructions · Control Panel Description · Stirring Bar Options

Angni AD400C Laboratory Aseptic Homogenizer Operation Manual
This manual describes the Angni AD400C laboratory aseptic homogenizer, including its components, control panel, and operating principles. It explains how to assemble the unit, insert the sterile homogenization bag, and start the homogenization process using the LCD control screen.
Safety guidelines, routine maintenance, and warranty information are also covered. The document details how to adjust speed and time settings, how to safely open the homogenizer door, and troubleshooting steps for common issues. This manual is written in Chinese.
Covers: Product Overview · Technical Parameters · Installation and Setup · Operation and Control · Safety Instructions · Maintenance and Warranty

Angni AD18 Operation Monitor User Manual
The AD18 operation monitor is a dedicated accessory for the AD18 laboratory high‑shear disperser. It consists of a monitor unit, data cable, mounting bracket and charger, and uses an embedded micro‑processor with an OLED display to provide real‑time speed, timing and battery information.
The manual describes the monitor’s specifications, how to mount it on the disperser, connect the data cable, charge the internal battery, and operate the device, including activation of the screen and power‑saving screen‑saver mode. This manual is written in Chinese.
Covers: Overview · Specifications · Assembly · Operation · Packing List

Angni AM200W-O Electronic Constant Speed Mixer User Manual
This manual describes the Angni AM200W-O electronic constant‑speed mixer, a laboratory device for mixing low‑ to high‑viscosity liquids. It includes product overview, technical parameters, safety guidelines, assembly steps, operating procedures, and maintenance instructions.
The document also contains warranty information, troubleshooting codes, and recommended accessories such as various stir‑bars. All instructions are aimed at ensuring reliable, safe, and efficient operation in a laboratory environment. This manual is written in Chinese.
Covers: Product Overview · Technical Parameters · Safety Instructions · Installation and Assembly · Operation · Maintenance
Latest Angni manuals
Angni AM110W-T Laboratory Electric Mixer User Manual
User Manual 4 pages · 670 KB · ZHThe Angni AM110W-T laboratory electric mixer user manual provides assembly steps, technical parameters, operation instructions, and maintenance guidelines.
Angni AD400C Laboratory Aseptic Homogenizer Operation Manual
User Manual 4 pages · 822 KB · ZHThe Angni AD400C laboratory aseptic homogenizer operation manual provides setup, usage, safety, and maintenance instructions.
Angni AD18 Operation Monitor User Manual
User Manual 2 pages · 497 KB · ZHUser manual for the Angni AD18 operation monitor that shows speed, run time and battery status for laboratory high‑shear dispersers.
Angni AM200W-O Electronic Constant Speed Mixer User Manual
User Manual 4 pages · 1.2 MB · ZHThe Angni AM200W-O electronic constant‑speed mixer user manual provides assembly, operation, maintenance and safety instructions.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Angni manuals
What power supply does the AM110W‑T mixer require?
It requires a single‑phase three‑wire 220 V, 10 A socket.
How do you start the mixer and set the speed?
Touch the start key on the touch panel; the default speed is 30 rpm, then use the numeric keys to set the desired rpm.
How do I start the homogenizer?
Press the “开/停” key; the LCD will show “工作” and the device will begin operating.
From: Angni AD400C Laboratory Aseptic Homogenizer Operation Manual
What happens if I open the homogenizer door while it is running?
The machine automatically stops and locks; the LCD displays the current status and the hammer plate stops striking.
From: Angni AD400C Laboratory Aseptic Homogenizer Operation Manual
How do I charge the AD18 monitor?
Insert the charger’s output plug into the monitor’s charging input socket and then plug the charger into a power outlet.
What information does the monitor display?
The screen shows dynamic speed, run time, battery level and whether the charger is connected.