DYNAMICS 11.0 Harmonic Response Analysis Example Fixed-Fixed Beam Training Manual
The manual explains step‑by‑step how to set up a beam model, define a harmonic analysis, apply loads, set damping, and run the solution in DYNAMICS 11.0. It is intended for users who need to study the dynamic response of a steel beam with two rotating machines.
The procedure covers clearing the database, reading the input file, selecting the harmonic analysis type, configuring analysis options, applying forces at specified nodes, defining a 5‑30 Hz frequency sweep with 25 steps, solving, and post‑processing results such as displacement‑frequency curves and phase‑angle relationships. This manual is written in Chinese.
Covers: Model Setup · Analysis Specification · Analysis Options · Load Application · Damping Settings · Frequency Sweep Definition
Latest Dynamics manuals
DYNAMICS 11.0 Harmonic Response Analysis Example Fixed-Fixed Beam Training Manual
User Manual 10 pages · 188 KB · ZHThis training manual shows how to perform a harmonic response analysis of a fixed‑fixed beam using DYNAMICS 11.0 software.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Dynamics manuals
How do I set the damping ratio?
Set the damping ratio to 0.02 (2%) via Solution > Load Step Opts > Time/Frequency > Damping.
From: DYNAMICS 11.0 Harmonic Response Analysis Example Fixed-Fixed Beam Training Manual
How many frequency steps are used?
The analysis uses 25 frequency steps between 5 Hz and 30 Hz.
From: DYNAMICS 11.0 Harmonic Response Analysis Example Fixed-Fixed Beam Training Manual