Agilent Manuals (Others)
Agilent PLgel 10 m MIXED-B Columns handbook
This document introduces the characteristics of Agilent PLgel 10 µm MIXED-B Columns for analyzing high molecular weight elastomers, including sample preparation methods, column models, mobile phase, injection volume, temperature and detection method.
File format: PDF Size:519 KB
Agilent SurePrint Technology. Content centered microarray design enabeling speed flexibility Manual
Agilent SurePrint Technology is content centered microarray design enabling speed and flexibility
File format: PDF Size:1613 KB
Agilent G2350A Atomic Emission Detector (AED) Manual
Agilent G2350A Atomic Emission Detector (AED) is a gas chromatograph-mass spectrometer that can detect carbon, sulfur, nitrogen, hydrogen, chlorine, phosphorus, and oxygen. The instrument uses molecular spectroscopy and atomic emission spectroscopy, which has high sensitivity, good selectivity, and wide measurement range.
File format: PDF Size:180 KB
Agilent 6890N Network Gas Chromatograph Manual
This document provides detailed specifications and features of the Thermo Scientific ISQ7000 GC-MS, including dimensions, weight, environmental conditions, safety and regulatory certifications.
File format: PDF Size:140 KB
Agilent 3000 Refinery Gas Analyzer Manual
Agilent 3000 Refinery Gas Analyzer (RGA) is a four-channel analyzer weighing 11.2 kg (24.8 lbs) and measuring 15.5 cm high x 47.2 cm wide x 42.0 cm deep (6.1 x 18.5 x 16.5 in.). It can be operated in an environment with a temperature range of 0 °C to 50 °C, relative humidity of 5 to 95% (non-condensing) and an altitude of up to 15,000 ft (4,572 m). It is compatible with mixtures that are in a gaseous phase at STP and typically used for compounds with BP<250 °C. Maximum sample pressure is less than 30 psig and recommended sample pressure is 5-10 psig.
File format: PDF Size:156 KB
Agilent 3000 Natural Gas Analyzer Manual
Agilent 3000 Natural Gas Analyzer (NGA) is a 2-channel gas chromatograph-mass spectrometer (GC-MS) analyzer that measures natural gas components and pollutants.
File format: PDF Size:128 KB
Agilent G2615A Bar Code Reader Label Vial Manual
This document provides the specifications for the Agilent Technologies G2615A barcode reader labels and vials to minimize errors caused by labels and/or vials. The document includes the dimensions and details of the labels and vials.
File format: PDF Size:331 KB
Agilent G2615A Bar Code Reader Unsupported Label Vial Manual
This document describes the unsupported label and vial specifications for the Agilent G2615A Bar Code Reader. Always use labels and vials that meet the specifications in this document to minimize label and/or vial induced errors.
File format: PDF Size:346 KB
Agilent 8453 UV-visible Spectroscopy Systems Manual
Agilent 8453 UV-visible spectroscopy systems are based on a PC-controlled spectrophotometer and a range of software products, each with features that meet the needs of specific user groups.
File format: PDF Size:42 KB
Agilent ChemStation Plus Manual
Agilent ChemStation Plus is a chemical laboratory software provided by Agilent. It supports multiple instrument types, including GC, LC, LC/MSD, CE, UV-visible spectrophotometer, and electrochemical analyzer. The software supports data management, data processing, and report generation.
File format: PDF Size:3021 KB
Agilent I-AS Clean Integrated Autosampler handbook
The document describes the Integrated Autosampler (I-AS) produced by Agilent Technologies for ultra-trace analysis. It is specifically designed for the Agilent 7500 Series ICP-MS and enables the high sensitivity of the 7500 Series to be fully utilized. The I-AS is ideal for semiconductor applications and any application involving ultra-trace analysis of elements where laboratory contamination may be a concern, such as clinical applications and seawater measurement. It can also automate various QA/QC control operations, including EPA protocols, when used with Agilent's optional Intelligent Sequencing Software.
File format: PDF Size:817 KB
Agilent 4890D Gas Chromatograph Manual
Agilent 4890D Gas Chromatograph Specification
File format: PDF Size:145 KB
Agilent 6850 Automatic Liquid Sampler G2880A Manual
File format: PDF Size:0 KB
Agilent G2565BA Microarray Scanner Bar Code Glass Specifications handbook(1)
This document describes the bar code and glass specifications of Agilent G2565BA microarray scanner
File format: PDF Size:61 KB
Agilent G2565BA Microarray Scanner Bar Code Glass Specifications handbook
This data sheet lists the specifications of the glass on which the active microarray is printed, and the region in which the microarray may be scanned.
File format: PDF Size:61 KB
Agilent ZORBAX SB-C18 RRHT Threaded Column Datasheet
The Agilent ZORBAX SB-C18 RRHT Threaded Column is designed for high-pressure operation (up to 600 bar) and is packed with a high-performance microparticulate C18 packing for high-speed reversed phase HPLC. The StableBond packing is made by chemically bonding a sterically-protected C18 stationary phase to a specially prepared, high purity ZORBAX porous silica microsphere. The special ZORBAX silica support is designed to reduce or eliminate strong adsorption of basic compounds. The densely covered, sterically protected, diisobutyl n-octadecylsilane stationary phase is chemically stable and gives longer column life. As a result, ZORBAX SB-C18 is a stable, reversed-phase packing that can be used for basic, neutral, or acidic samples. It is particularly well suited for use with aggressive mobile phases (for example, pH <2, high ionic strength, ion-pair additives, etc.) since the steric protection of the bonded phase resists degradation caused by such mobile phases. This material has also been shown to be stable when operated at temperatures up to 90 °C. These characteristics are particularly important for use in methods that need long-term stability and reproducibility. ZORBAX SB-C18 is especially suited in applications that use high-sensitivity detectors that require low backgrounds (for example, mass spectrometers). The uniform, spherical, ZORBAX SB-C18 particles have a controlled pore size of 80Å.
File format: PDF Size:77 KB
Agilent ZORBAX Eclipse XDB-C18 RRHT Threaded Column Datasheet
This document is the datasheet of Agilent Eclipse XDB-C18 RRHT Threaded Column
File format: PDF Size:84 KB
Agilent ZORBAX Extend-C18 RRHT Threaded Column Datasheet
Agilent ZORBAX Extend-C18 RRHT threaded column for high pH and high pressure liquid chromatography
File format: PDF Size:89 KB
Agilent ZORBAX Eclipse XDB-C8 RRHT Threaded Column Datasheet
Agilent ZORBAX Eclipse XDB-C8 RRHT Threaded Column is a high-speed reversed-phase HPLC column designed for higher pressure operation (up to 600 bar) and packed with a high-performance microparticulate C8 packing. The column utilizes the eXtra-Dense Bonding (XDB) technology to bond organo-silane ligands to an ultra-pure silica support, and employs double endcapping to protect the support from dissolution in mobile phases of intermediate and higher pH. It is especially useful for the separation of acidic, basic, and other highly polar compounds by reversed-phase liquid chromatography.
File format: PDF Size:89 KB
Agilent ZORBAX SB-C8 RRHT Threaded Column Datasheet
Agilent ZORBAX SB-C8 RRHT threaded columns are specially designed for higher pressure operation and are packed with a high-performance microparticulate C8 packing for high-speed reversed-phase HPLC. The StableBond packing is made by chemically-bonding a sterically-protected C8 stationary phase to a specially-prepared, high-purity ZORBAX porous silica microsphere. The special ZORBAX silica support is designed to reduce or eliminate strong adsorption of basic compounds. The densely-covered, sterically-protected, diisopropyl n-octylsilane stationary phase is chemically stable and gives longer column life. It is particularly well-suited for use with aggressive mobile phases (for example, pH <2, high ionic strength, ion- pair additives, etc.) since the steric protection of the bonded phase resists degradation caused by such mobile phases. This material has also been shown to be stable when operated at temperatures up to 80 °C. These characteristics are particularly important for use in methods that need long-term stability and reproducibility. ZORBAX SB-C8 is especially suited in applications that use high-sensitivity detectors that require low backgrounds (for example, mass spectrometers). The uniform, spherical, ZORBAX SB-C8 particles have a controlled pore size of 80Å. The columns are 250 mm long, 4.6 mm inner diameter, and the particle size is 5 μm.
File format: PDF Size:81 KB