Shenyang Yushi Pioneer VM Series Handheld LED UV Lamp User Manual

The Shenyang Yushi Pioneer VM series handheld LED UV lamp user manual provides product overview, specifications, safety guidelines, and operating instructions.


Shenyang Yushi Pioneer VM Series Handheld LED UV Lamp User Manual - cover page
Brand
Shenyang Yushi Pioneer
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
5
File format
PDF
File size
185 KB
Published
28 September, 2026
Updated
28 September, 2026
MD5 checksum
1F4142568FC8024B98F818269C2022FB

About this manual

The VM series handheld LED UV lamps are designed for fluorescence magnetic‑particle testing, fluorescence penetrant testing and other nondestructive inspection applications. They feature a cold‑light source, high illumination, low power consumption and meet the national NDT standard NB/T47013‑2015.

The manual includes an introduction to the instrument, its scope of use, detailed product description with features, technical parameters, configuration list, safety precautions and references to related standards and documents. This manual is written in Chinese.

What's inside

  • Instrument Introduction
  • Scope of Use
  • Product Description
  • Features and Performance
  • Technical Parameters
  • Configuration List
  • Precautions
  • Related Documents

Specifications

Maximum UV intensity at 38 cmVM10: 10 000 µW/cm², VM30: 13 000 µW/cm², VM70: 20 000 µW/cm²
UV wavelength365 nm (UV‑A)
Battery typeICR18650 or ICR26650 Li‑ion
Continuous work time (low brightness)VM10: 4 h, VM30: 5 h, VM50: 18 h, VM70: 5 h
Weight (including battery)VM10: 140 g, VM30: 240 g, VM50: 520 g, VM70: 610 g

Frequently asked questions

What is the recommended charging environment for the lamp?

The optimal charging environment is a temperature of 18‑30 °C and humidity of 25‑62 %.

What is the lamp’s IP protection rating?

The lamp complies with IEC 60529 IP66, offering dust‑tight and water‑jet protection.