User manual for the Four Star iCAN-MA CAN bus isolator, covering features, specifications, installation and testing.
About this manual
The iCAN-MA is a CAN bus isolator produced by Four Star Electronics. It provides high‑voltage isolation between CAN ports and power ports, supports adaptive data rates up to 1 Mbps, and is designed for use in hazardous mining environments.
The manual describes the device’s technical parameters, wiring diagrams, installation methods, isolation voltage testing procedures, and ordering information, helping users configure and maintain the isolator safely. This manual is written in Chinese.
What's inside
- Overview
- Product Features and Technical Parameters
- Schematic Diagram
- Physical Appearance and Component Description
- Installation and Use Guide
- Isolation Voltage Test
- Ordering Information
Specifications
| Isolation voltage (CAN‑CAN) | 5000 V AC |
|---|
| Isolation voltage (CAN‑Power) | 4500 V AC |
|---|
| Communication speed | 0 ~ 1 Mbps (adaptive) |
|---|
| Power supply voltage | 7 ~ 40 V DC or 5 V DC (select one) |
|---|
| Power consumption | ≈0.5 W |
|---|
| Operating temperature | -40 °C ~ +85 °C |
|---|
| Dimensions (L×W×H) | 85 mm × 55 mm × 25 mm |
|---|
| Weight | 100 g |
|---|
| Terminal resistance | 120 Ω (selectable) |
Frequently asked questions
What is the isolation voltage rating between the two CAN ports?
The isolation voltage between CAN1 and CAN2 ports is rated at 5000 V AC.
What communication speeds does the iCAN-MA support?
It supports adaptive communication speeds from 0 up to 1 Mbps.
How can the device be powered?
It can be powered by an external 7‑40 V DC source or a 5 V DC source, with either option selected.
How is the isolation voltage tested?
Connect the ports as shown and use a dielectric tester; the maximum test voltage is 5000 V AC for 1 minute without leakage.