Key facts
- Manuals
- 4
- Models
- 1
- Languages
- ZH
- Last added
- 2026-10-01
Unico models by category
Featured Unico manuals

Unico UV-4802 UV/VIS Spectrophotometer User Manual
The UV-4802 is a double‑beam UV/VIS spectrophotometer with a pulse xenon lamp, 1200 lines/mm diffraction grating and a 7‑inch back‑lit LCD display. It offers high stability, low stray light and a wide wavelength range for laboratory analysis.\n\nThis manual describes the instrument’s main functions, hardware configuration, calibration procedures, data acquisition, and optional accessories. It also lists the technical specifications, safety notes, and troubleshooting tips to help users operate the spectrophotometer efficiently. This manual is written in Chinese.
Covers: 主要功能 · 主要技术指标 · 标准配置 · 附件介绍 · 主控制界面 · 标准曲线定量分析

Unico UV-4802/UV-48025 UV-Visible Spectrophotometer Product Leaflet
The UV-4802/UV-48025 features a large LCD screen and a dual‑beam optical design that provides high stability and low ozone emission. It supports a variety of test modes such as fixed‑wavelength, multi‑wavelength (up to 10 wavelengths), spectral scanning, and DNA/Protein analysis, with optional bandwidths of 1.8 nm or 2 nm.
Standard accessories include the main unit, Unico advanced computer software, cuvette holders, standard quartz cuvettes, a USB interface, power and computer cables, and a dust cover. Technical specifications cover a spectral range of 190‑1100 nm, scan speeds up to 2500 nm/min, and a compact size of 625 × 405 × 280 mm. This manual is written in Chinese.
Covers: Main Functions · Standard Configuration · Technical Specifications
Unico WFJ2100 UV-2100 Spectrophotometric Meter User Manual
This manual provides detailed instructions for using the Unico WFJ2100 UV‑2100 spectrophotometric meter. It describes the device’s hardware layout, basic operation, measurement modes, and how to configure wavelength and transmission settings.
The document also includes information on the RS‑232C communication interface, error codes, calibration procedures, and maintenance tips to ensure accurate and reliable performance. This manual is written in Chinese.
Covers: Introduction · Technical Specifications · Operation and Measurement Modes · Wavelength Settings · RS‑232C Interface · Error Codes and Troubleshooting
UNICO UV-2102C/PC/PCS Spectrophotometric Meter User Manual
This manual describes the UNICO UV‑2102C/PC/PCS UV/VIS spectrophotometer, its optical performance, hardware layout, and safety precautions. It includes specifications such as wavelength range, resolution, and display details.
The guide explains how to power on the device, run the warm‑up and self‑test procedures, adjust measurement parameters, and communicate via the RS‑232C interface. Maintenance tips and troubleshooting steps are also provided. This manual is written in Chinese.
Covers: Introduction · Specifications · Operation · Self‑test · RS‑232 Communication · Maintenance
Latest Unico manuals
Unico UV-4802 UV/VIS Spectrophotometer User Manual
User Manual 14 pages · 2.6 MB · ZHThe Unico UV-4802 UV/VIS spectrophotometer user manual provides operating instructions, technical specifications, and accessory information.
Unico UV-4802/UV-48025 UV-Visible Spectrophotometer Product Leaflet
Product Leaflet 1 pages · 244 KB · ZHThe Unico UV-4802/UV-48025 is a large‑screen, dual‑beam UV‑Vis spectrophotometer with adjustable bandwidth, multiple test modes and advanced software.
Unico WFJ2100 UV-2100 Spectrophotometric Meter User Manual
User Manual 15 pages · ZHUser manual for the Unico WFJ2100 UV‑2100 spectrophotometric meter covering operation, settings and troubleshooting.
UNICO UV-2102C/PC/PCS Spectrophotometric Meter User Manual
User Manual 25 pages · 1.1 MB · ZHThe UNICO UV-2102C/PC/PCS spectrophotometric meter user manual provides operation, self‑test, and parameter settings for the instrument.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Unico manuals
What is the wavelength range of the UV-4802?
The UV-4802 covers a wavelength range of 190 nm to 1100 nm.
How many cuvette holders are included with the UV-4802?
The instrument includes a six‑position cuvette rack and a single‑hole cuvette holder.
What bandwidth options are available for the UV-4802/UV-48025?
The instrument offers a 1.8 nm bandwidth for the UV-4802 model and a 2 nm bandwidth for the UV-4802S model.
From: Unico UV-4802/UV-48025 UV-Visible Spectrophotometer Product Leaflet
What is the spectral range of the spectrophotometer?
It covers 190 nm to 1100 nm with an accuracy of ±0.3 nm.
From: Unico UV-4802/UV-48025 UV-Visible Spectrophotometer Product Leaflet
What is the wavelength range of the WFJ2100?
The instrument measures from 200 nm to 1000 nm.
From: Unico WFJ2100 UV-2100 Spectrophotometric Meter User Manual
How do I select the measurement mode?
Use the MODE switch to choose between T, A, C, and F modes.
From: Unico WFJ2100 UV-2100 Spectrophotometric Meter User Manual