DeVilbiss T-AGB-862/872/873/874/879/882 Service Manual
The manual begins with safety precautions, warning users about fire hazards, required ventilation, and the need for protective equipment when using the spray gun. It also explains the proper handling of flammable solvents and the importance of using clean, dry air.
Subsequent sections cover installation of the gun, adjustment of air and fluid pressures, operation procedures, routine maintenance, parts replacement, and a service‑check checklist. Detailed parts lists, torque specifications, and accessory information are provided to assist technicians in servicing the equipment. This manual is written in Japanese.
Covers: Safety Precautions · Installation · Operation · Maintenance · Parts Replacement · Service Check
Devilbiss JGX-508H Spray Gun Manual
This manual covers essential safety precautions for using the JGX-508H spray gun, including fire‑explosion hazards, proper grounding, and personal protective equipment. It also details installation steps, recommended air and paint pressures, and correct operation techniques.
Further sections describe preventive maintenance, cleaning procedures, lubrication recommendations, part replacement, and troubleshooting with a parts list and accessories. Technical specifications such as maximum air and paint pressures are also provided. This manual is written in Chinese.
Covers: Safety Precautions · Installation · Operation · Preventive Maintenance · Repair and Inspection · Parts List
Latest DeVilbiss manuals
DeVilbiss T-AGB-862/872/873/874/879/882 Service Manual
Service Manual 8 pages · 550 KB · JAThis service manual provides safety guidelines, setup, operation, maintenance, and parts information for DeVilbiss T‑AGB‑862/872/873/874/879/882 compact…
Devilbiss JGX-508H Spray Gun Manual
User Manual 4 pages · 369 KB · ZHThe Devilbiss JGX-508H spray gun manual provides safety guidelines, setup, operation, maintenance, and parts information.
Which document do I need?
Service Manual
Disassembly, diagnostics and part numbers, for repair.
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in DeVilbiss manuals
How should the CYL air pressure be set?
Set the CYL air pressure between 0.34 MPa and 0.49 MPa as instructed in the adjustment steps.
From: DeVilbiss T-AGB-862/872/873/874/879/882 Service Manual
What is the maximum air pressure the JGX‑508H can handle?
The maximum air pressure is 9 bar.
What pressure should not be exceeded during operation?
Do not exceed a working pressure of 0.69 MPa.