Xinyide Technology SDI7768 Single-Phase Multifunction Anti-Theft Metering Chip Datasheet
The SDI7768 chip provides comprehensive metering functions for single‑phase anti‑theft applications. It measures active power, reactive power, and various energy quantities while delivering two independent power‑measurement channels and RMS voltage measurement. The device supports full‑digital gain, phase and offset calibration and offers both SPI and RSIO serial interfaces for communication with external MCUs.
Key features include a typical power consumption of 32 mW, an internal 2.5 V±3 % reference, SSOP‑24 package, and built‑in power‑monitoring circuitry that resets the chip when AVDD falls below 4 V and enables normal operation above 4.3 V. The datasheet details pin assignments, electrical limits, and typical application circuits for anti‑theft metering. This manual is written in Chinese.
Covers: Overview · Functional Block Diagram and Pin Description · Pin Description · Electrical Characteristics · Power Monitoring · Reset Operation
Latest 芯易德科技 manuals
Xinyide Technology SDI7768 Single-Phase Multifunction Anti-Theft Metering Chip Datasheet
Datasheet 37 pages · 1.8 MB · ZHThe SDI7768 is a single‑phase multifunction anti‑theft metering chip that measures active and reactive power, offers dual power‑measurement channels…
Which document do I need?
Datasheet
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in 芯易德科技 manuals
What serial interfaces does the SDI7768 support?
The chip provides two serial interfaces: SPI and RSIO.
From: Xinyide Technology SDI7768 Single-Phase Multifunction Anti-Theft Metering Chip Datasheet
What are the voltage thresholds for power‑monitoring reset?
The device resets when AVDD drops below 4.0 V ± 0.1 V and operates normally when the voltage is above 4.3 V ± 0.1 V.