Key facts
- Manuals
- 1
- Languages
- EN
- Last added
- 2026-09-28
Featured O2S manuals

O2S Probe Style Oxygen Sensor Data Sheet
The O2S Probe Style oxygen sensor series offers zirconium dioxide sensing elements, non‑consumption technology, and an integral heating element. Available in 80 mm, 220 mm and 400 mm probe lengths, the sensors operate without temperature stabilization or reference gas and provide a linear output signal.
Key specifications include an oxygen pressure range of 2–3000 mbar, heater supply voltages of 4 V DC (Porous Lid Cap) or 4.35 V DC (Full Porous Cap), and permissible gas temperatures from –100 °C to 250 °C (or up to 400 °C for high‑temp versions). Electrical connections use a Molex 5‑pin connector, and detailed ordering information is provided for each model variant.
Covers: Features · Specifications · Electrical Connection · Outline Drawings · Characteristics · Ordering Information
Latest O2S manuals
O2S Probe Style Oxygen Sensor Data Sheet
Datasheet 3 pages · 205 KB · ENData sheet for O2S Probe Style oxygen sensors detailing features, specifications, electrical connections, and ordering information.
Which document do I need?
Datasheet
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in O2S manuals
What is the oxygen pressure range of the O2S Probe Style sensor?
The sensor measures oxygen pressure from 2 mbar up to 3000 mbar.
What heater supply voltage is required for the Porous Lid Cap version?
It requires a 4 V DC supply with a tolerance of ±0.1 V.