Key facts
- Manuals
- 1
- Languages
- EN
- Last added
- 2026-09-28
Featured General Monitors manuals

General Monitors S4000TH Intelligent Sensor Instruction Manual
This manual covers the complete setup and use of the S4000TH Intelligent Sensor, including safety warnings, mounting dimensions, wiring instructions, and terminal connections. It also explains the sensor's operating modes, calibration procedures, and HART/Modbus communication settings.
Key sections include a Quick Start Guide, detailed installation steps, user-selectable options, maintenance recommendations, fault code troubleshooting, and full technical specifications such as power requirements, relay ratings, and environmental limits.
Covers: Quick Start Guide · Mounting and Wiring · Installation · Operation · Calibration · Maintenance
Latest General Monitors manuals
General Monitors S4000TH Intelligent Sensor Instruction Manual
User Manual 68 pages · 545 KB · ENThe General Monitors S4000TH Intelligent Sensor instruction manual provides installation, operation, maintenance, troubleshooting, and Modbus interface…
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in General Monitors manuals
What is the maximum recommended cable length between the S4000TH and its power supply?
The maximum distance is 2,000 feet (610 meters), and each cable run should be as short as possible.
From: General Monitors S4000TH Intelligent Sensor Instruction Manual
What are the relay ratings for the S4000TH sensor?
The relays are rated for 8 A at 250 VAC or 8 A at 30 VDC resistive maximum.
From: General Monitors S4000TH Intelligent Sensor Instruction Manual