Garlock STYLE #9000 EVSP Simplified Sets Installation Guide
This guide provides step‑by‑step instructions for installing the Garlock STYLE #9000 EVSP Simplified sealing sets. It includes the ring‑stack arrangement, required stuffing‑box depth measurements, and selection of the appropriate 5‑, 6‑, or 7‑ring set.
The document also details compression targets, gland‑stud torque values, and an alternate torque‑based method to achieve the correct gland load. Follow the procedures to ensure proper sealing performance and consistent torque on the gland studs.
Covers: Ring Stack Arrangement · Required Measurements · Ring Set Selection · Bushing and Braided Ring Installation · Compression and Torque Guidelines · Actuation and Re‑torquing Procedure
Latest Garlock manuals
Garlock STYLE #9000 EVSP Simplified Sets Installation Guide
Installation Guide 5 pages · 420 KB · ENInstallation guide for Garlock STYLE #9000 EVSP Simplified Sealing Sets, covering ring stack layout, required measurements, and torque procedures.
Which document do I need?
Installation Guide
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in Garlock manuals
How many rings should be used for a #9000 EVSP Simplified set?
Use a 7‑ring set whenever possible; otherwise select 5 or 6 rings based on the stuffing‑box depth chart.
From: Garlock STYLE #9000 EVSP Simplified Sets Installation Guide
What torque should be applied to the gland studs?
Aim for a gland load of 3800 psi or 1.5 × the system pressure, which can be achieved by measuring bolt torque.
From: Garlock STYLE #9000 EVSP Simplified Sets Installation Guide